FlameGuard™
|
Now with FlameGuard™
Poly-Classic Columns have redefined the standards for versatility, style,
and freedom from maintenance for residential and commercial column
installations. They offer the traditional aesthetics of
architecturally proportioned columns with the non-traditional benefits of
the most advanced construction materials in the world today.
Now with FlameGuard™, Poly-Classic Columns set a new industry
standard---the beauty of flame resistance. They are the first
rotocast fiberglass-reinforced polymer (FRP) columns to pass the ASTM E,
84-01 test which measures the flame spread and smoke development of
building components in a fire.
Poly-Classic
FRP Columns are available in tapered fluted columns, tapered smooth
columns, non-tapered smooth columns, square non-tapered columns, square
fluted and raised panel columns. We can also manufacture any size
column to your exact specifications. Whether exterior columns are
needed or interior columns, we have what you are looking for.
Features & Benefits
of FlameGuard™
Poly-Classic Columns now have a Flame Spread Index (FSI) of 15. This
index puts the Poly-Classic Column in a Class I Flame-Spread
classification under the 1997 uniform fire code. This is an industry
first for FRP columns.
Poly-Classic
Columns also have a Smoke Developed Index (SDI) of 335. This index
is well below the allowable SDI index of 450. This is also an
industry first for FRP Columns.
Industry
Standard FRP Columns have a typical Flame Spread Index (FSI) of 70-85 and
a Smoke Developed Index (SDI) of 900-1025.
Specifications
UNROUNDED FSI |
15.5 |
UNROUNDED SDI |
335.8 |
FS*TIME AREA (Ft*Min) |
30.2 |
SMOKE AREA (%*Min) |
273.2 |
|
|
Observations During Test |
|
IGNITION TIME (Min:Sec) |
3:31 |
MAXIMUM FLAME FRONT ADVANCE (Ft) |
7.0 |
TIME TO MAXIMUM ADVANCE (Min:Sec) |
10:00 |
MAXIMUM TEMP. AT EXPOSED TC(*F) |
563 |
TIME TO MAXIMUM TEMP (Min:Sec) |
9:57 |
TOTAL FUEL BURNED (Cu.Ft.) |
52.4 |
DRIPPING (Min:Sec) |
None |
FLAMING ON FLOOR (Min:Sec) |
8:15 |
AFTERFLAME TOP (Min:Sec) |
3:00+ |
AFTERFLAME FLOOR (Min:Sec) |
3:00+ |
|
Porch columns with tuscan capital.
Back porch columns with a decorative attic
base.
Beautiful exterior porch columns with decorative
scamozzi capitals. These columns for a 2 story home are over
20' tall.
Our columns are not only used as exterior
columns. These tuscan columns were used to add some character
to an entryway.
|